Dongguan, China Vertical injection molding machines Technical selection starts with your part →
Application · Sensor components

Sensor encapsulation

A housing, coil or cable end is enclosed by a short flow, using a barrel matched to a small shot.

Application group
Sensor components
Insert type
A sensor housing, coil, cable end or metal shell.
Electronic connectors, switches and overmolded components on a workbench

The part

Pressure and hall-effect sensor bodies, temperature probe sleeves and inductive sensor faces. Reed switch capsules, flow sensor inserts, cable-outlet bodies and small potted housings. The plastic usually seals the assembly as well as forming it.

Common materials

PBT, PA6/PA66, PPS, PEEK and PC for bodies, with TPE or TPU where a soft sealing lip is molded. The choice follows the chemical, UV and temperature exposure at the sensor's location.

Why a vertical clamp

Encapsulation depends on the insert sitting flat and staying covered, so the nest has to be open at the side the operator can see. A vertical clamp holds the housing and the cable exit in a fixed lower half, the moving half comes straight down and the shot fills from the top, so the sealing surfaces stay visible through the whole loading step. Where the shot is small, the injection unit matters as much as the clamp: a barrel sized for a much larger part leaves the melt at temperature far longer than the shot needs, and that residence time is part of what the material sees.

How the insert is loaded

The housing is placed in a shaped nest, the coil or cable end is seated in its slot, and the assembly is checked for insertion depth and orientation before clamp close; a light insert is held by a pin or a spring. A robot can load the same nest from trays without the nest being redesigned.

What the buyer is really asking

Whether the plastic seals the insert without a path for a leak, and whether the melt reaches the thin section around the cable exit. Whether the housing survives the melt temperature and the insert's own tolerance spread. Whether the finished part passes the leak or insulation test the customer already applies.

Structure that usually follows

Data that decides it

  1. Sensor drawing with insert material, sealing surfaces and where plastic may cover.
  2. Plastic volume per part, cavity count, wall thickness and the leak or insulation test required.
  3. Material grade, with the chemical, UV and temperature exposure the sensor sees in service.
  4. Mold concept: nest design, gate location, venting, and whether the tool already exists.
  5. Target cycle and whether housings arrive loose, in trays or on carrier tape.

What can go wrong

The insert can move and thin a wall on one side, air can be trapped and leave a void through the seal, the housing can deform under injection pressure, and a weld line can leak. A cable exit can flash, and an injection unit far oversized for the shot narrows the process window. Whether this appears is decided by nest support, venting, gate position, material viscosity and shrinkage, mold temperature, injection speed and the insert's dimensional spread.

Naming a risk is not the same as removing it: which of these applies to your part is settled in technical review.

Related solutions

Tell us the part and the insert

A photograph of the part with the insert in place, the plastic grade and the mold size start the review. Which of the points above applies to your part is settled there, not on this page.

Send this part for review